Table 12. Output_Pulse X commands
Command Type Command Comments
Output_Pulse X On
term123 Output_Pulse X
On <time>
Response:
OUTPUT_PULSE X ON
<time>: OK
Response, when pulse time expires:
OUTPUT X: Y
The X refers to output pin number, X=
1,2,3,4,5,6,7,8,9,all.
The Y refers to either ON or OFF.
Response, if another pulse command has already been
issued:
OUTPUT_PULSE X ON
<time>:
OUTPUT X LOCKED
Fail response, if invalid <time> value:
ERROR( Unknown Command )
Fail response, if NITZ network service is not supported
and <time> value was more than 23 hours 59 minutes
and 59 seconds:
OUTPUT_PULSE ON <time>:
ERROR( Network Time
Missing )
The command sets to
output pin X on for a
requested time interval,
that is, pulse
Output_Pulse X Off
term123 Output_Pulse X
Off <time>
Response:
OUTPUT_PULSE X OFF
<time>: OK
Response, when pulse time expires:
OUTPUT X:Y
Response, if another pulse command has already been
issued:
OUTPUT_PULSE X OFF
<time>:
OUTPUT X LOCKED
Fail response, if invalid <time> value:
The command sets to
output pin X off for a
requested time interval,
that is, pulse