Strona 1 - NOKIA 12 GSM MODULE

Copyright © 2002-2004 Nokia. All rights reserved. Issue 2.0 9231722 NOKIA 12 GSM MODULE REMOTE I/O CONTROL GUIDE

Strona 3

4. GETTING STARTED 4.1 SETTING UP THE CONFIGURATOR ENVIRONMENT To use Configurator, the following tools are needed: • Nokia 12 GSM Module (RX-2 or

Strona 4

When you have completed the above steps, Configurator automatically establishes a connection between the PC and the Nokia 12 GSM Module when Configur

Strona 5 - ACRONYMS AND TERMS

4.4 READING AND WRITING PARAMETERS To read parameter values from the Nokia 12 GSM Module and write parameter values to it, use Configurator. Each Co

Strona 6 - 1. ABOUT THIS DOCUMENT

Characters accepted for the message identifier are defined in Chapter 7, except the space characters. Note: You cannot use the Remote I/O control i

Strona 7 - 2. INTRODUCTION

4.6 SETTING THE SMS CENTRE ADDRESS A dialog for setting the SMS centre address with the Nokia 12 Configurator (GSM Settings -> Advanced -> Sho

Strona 8

SIM card and the Nokia 12 GSM Module memory are full. It is recommended to select the option “Remove oldest message when new arrives” for the Remote

Strona 9 - 3. SECURITY

5. OPTIONAL CONFIGURATIONS 5.1 DISABLING ACKNOWLEDGEMENTS The Nokia 12 GSM Module acknowledges whether or not a text message has successfully command

Strona 10

Figure 4. General settings If you select the Disable acknowledgements option, only response messages to acknowledgement messages are disabled. The f

Strona 11 - 4. GETTING STARTED

• Response messages to password change messages (see Chapter 9.3.1) • Response messages to pulse cancel messages (see Chapter 9.3.8) 5.2 SECURITY S

Strona 12 - 4.3 MANDATORY SETTINGS

Contents ACRONYMS AND TERMS ...1 1. ABOUT THIS DO

Strona 13

Figure 5. Security settings Authentication A user-specified password can further secure the communication between a mobile handset and the Nokia 12

Strona 14

The length of the password is 1- 8 characters, and it is case sensitive. It accepts characters defined in Chapter 7, except space characters. The pas

Strona 15

Figure 6. Setting aliases for device commands In the Aliasing dialog, you can replace the predefined commands with user-specified commands (aliases)

Strona 16

Characters accepted in aliases are defined in chapter 7. Note: If an alias is defined, the default command will be disabled. There can be only one

Strona 17 - 5. OPTIONAL CONFIGURATIONS

Note: In digital input, an alarm can be triggered when the state of the digital input changes. See chapter 9.3.3 for more information. Figure 7.

Strona 18

values set here will take effect the next time the Nokia 12 GSM Module is powered up. Check the box in the Default Output Settings window to set the

Strona 19 - 5.2.1 Authorised numbers

6. INPUT/OUTPUT PIN DESCRIPTIONS The Nokia 12 GSM Module has input and output pins on the M2M system connector, which can be controlled using the se

Strona 20

Table 2. PIN descriptions Name Analog/Digital R/W Pin Number (*) Input 1 Analog Read 36 Input 2 Analog Read 20 Input 3 Analog Read 19 Input

Strona 21 - 5.3 ALIASING

Figure 8. Port settings in Configurator Note: You can see the available I/O pins in the Module Configuration dialog when you change the settings. S

Strona 22

7. SUPPORTED CHARACTERS The characters listed in Table 4 are supported for: • Message identifier • Password • Aliasing The list is derived from t

Strona 23 - 5.4 INPUT SETTINGS

9.3.4 Reading Outputs...34 9.3.5 Writing Outputs ...

Strona 24

8. COMMAND SYNTAX The command syntax of control messages varies according to the activated options. There may also be spaces in aliases defined for c

Strona 25

9. REMOTE I/O CONTROL SMS COMMANDS The following chapter describes the commands and status messages available in the Remote I/O control. Status mess

Strona 26

OUTPUT_SET ALL OFF Set all outputs OFF OUTPUT_INVERT ALL Inverts all outputs OUTPUT PULSE ALL ON * All outputs pulse ON * OUTPUT_PULSE ALL OFF * All

Strona 27

Note: If an alias is defined, the default command will be disabled. There can be only one effective command or alias for each function at a time. An

Strona 28

Table 6. Commands for the password control. Command Type Command Comments Changing Password term123 passWORD Change_PWord wordPASS OK Response: CH

Strona 29 - 7. SUPPORTED CHARACTERS

Table 7. The Input_Get X commands Command Type Command Comments Input_Get All term123 Input_Get All Response: INPUT_GET ALL: OK INPUT1: Y INPUT2:

Strona 30 - 8. COMMAND SYNTAX

9.3.3 Subscribing to Input Alarms To subscribe to input state changes, that is, alarms, use the Input_Get_Change X commands. All example control mes

Strona 31 - 9.1 COMMANDS

Table 8. Input_Get_Change commands for alarm functionality Command Type Command Comments Input_Get_Change All Term123 Input Get Change All Respons

Strona 32 - 9.2 STATUS MESSAGES

INPUT 11: Y The Y varies according to the input pin state and it can be: xxxx mV if the input is in analog mode (pins 1-3) (xxxx=value between 0-2800

Strona 33 - 9.3.1 Changing the Password

Table 9. Output_Get X commands Command Type Command Comments Output_Get All term123 Output_Get All Response: OUTPUT_GET ALL: OK OUTPUT 1: Y OUTPU

Strona 34 - 9.3.2 Reading Inputs

Legal Notice Copyright © 2002-2004 Nokia. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this

Strona 35

Table 10. Output_Set X commands Command Type Command Comments Output_Set X On term123 Output_Set X On Response: OUTPUT_SET Z ON: OK OUTPUT Z: ON T

Strona 36

OUTPUT 3: OFF OUTPUT 4: OFF OUTPUT 5: OFF OUTPUT 6: OFF OUTPUT 7: OFF OUTPUT 8: OFF OUTPUT 9: OFF 9.3.6 Inverting Outputs Use the Output_Invert X com

Strona 37

OUTPUT 7: X OUTPUT 8: X OUTPUT 9: X The X refers to either ON or OFF 9.3.7 Output Pulses Use the Output_Pulse X Y commands to set digital output sta

Strona 38 - 9.3.4 Reading Outputs

Table 12. Output_Pulse X commands Command Type Command Comments Output_Pulse X On term123 Output_Pulse X On <time> Response: OUTPUT_PULSE

Strona 39 - 9.3.5 Writing Outputs

ERROR( Unknown Command )Fail response, if NITZ network service is not supported and <time> value was more than 23 hours 59 minutes and 59 secon

Strona 40

X” command. Note that all example control messages in this chapter use the “term123” identifier string and the password property is set off (see Tabl

Strona 41 - 9.3.6 Inverting Outputs

Case Initial state Control message Control message sent when 3s passed a) ON Term123 Output_pulse 1 ON 5s b) ON Term123 Output_pulse 1 OFF 5s c

Strona 42 - 9.3.7 Output Pulses

9.3.9 Location information Figure 11. GPS support configured to serial port 1 You can query location information from the Nokia 12 GSM Module if an

Strona 43

Note: You cannot connect a GPS device to serial port 2. It is always in the M2M system protocol use. Note: You can connect only one GPS device to t

Strona 44

Table 14. Location_get Command Type Command Comments Location_get term123 Location_get Response: LOCATION: LATITUDE: AA, BBBBBBBBB, C LONGITUDE:

Strona 45

ACRONYMS AND TERMS Acronym/term Description ASCII American Standard Code for Information Interchange AT Attention CORBA Common Object Request Brok

Strona 46

10. SAFETY INFORMATION Read these simple guidelines as they contain important safety information. Breaking the rules may be dangerous or illegal and

Strona 47 - 9.3.9 Location information

you can utilize Network Services. Your service provider may need to give you additional instructions for their use and explain what charges will appl

Strona 48

systems. For more information, check with the manufacturer or it’s representative of your vehicle or any equipment that has been added. Only qualifi

Strona 49

49/49• Do not drop, knock, or shake the device. Rough handling can break internal circuit boards and fine mechanics. • Do not use harsh chemicals

Strona 50 - 10. SAFETY INFORMATION

1. ABOUT THIS DOCUMENT This document describes how the Nokia 12 GSM module can be used in Remote I/O control mode. The methods for controlling a modu

Strona 51 - 10.4 VEHICLES

2. INTRODUCTION 2.1 GENERAL The Nokia 12 GSM Module provides wireless connectivity and remote management possibilities for machine-to-machine (M2M) a

Strona 52 - 10.6 CARE AND MAINTENANCE

Monitor a device Find out if a device is already on or off Receive alarm messages if a device has been switched on or off Receive alarm messages if

Strona 53

3. SECURITY There are different levels of access control for the Remote I/O control: message identifier, password, and authorised numbers. Also the a

Komentarze do niniejszej Instrukcji